The Relationship between Physical Environmental Conditions of Dormitories and Acute Respiratory Tract Infections (ARTI) at MAN 3 Palembang City in 2026
DOI:
https://doi.org/10.69930/ajer.v3i3.972Keywords:
Acute Respiratory Track Infections (ARTI); Dormitory Physical Environment; Lighting; VentilationAbstract
Acute Respiratory Tract Infection (ARTI) remains a common ailment in dormitory settings. Substandard physical environmental conditions within dormitories can increase the risk of ARTI among residents. Environmental factors suspected to be associated with ARTI incidence include ventilation, air temperature, occupancy density, lighting, and humidity. This study aimed to determine the relationship between the physical environmental conditions of the dormitory and the incidence of ARTI among students at the MAN 3 Palembang City Dormitory in 2026. A quantitative method with a cross-sectional design was employed. The study was conducted from January to June 2026 at the MAN 3 Palembang City Dormitory, involving a sample of 83 respondents selected via Simple Random Sampling. Data were collected through observation, direct measurement of the dormitory's physical environmental conditions, and interviews using a checklist. Data analysis was performed using the Chi-Square test with a 95% confidence level. The results showed that out of the 83 respondents, 30 (36.1%) suffered from ARTI, while 53 (63.9%) did not. Bivariate analysis revealed no significant relationship between ARTI incidence and ventilation (p=1.000), occupancy density (p=0.201), or humidity (p=1.000). However, a significant relationship was found between lighting and ARTI incidence (p=0.004), air temperature and ARTI incidence (p=0.016). Lighting and air temperature was identified as a physical environmental factor associated with ARTI incidence, whereas ventilation, occupancy density, and humidity did not show a significant relationship with ARTI incidence.
References
1. Bender RG, Sirota SB, Swetschinski LR, Dominguez R, Novotney A, Wool EE, et al. Global, regional, and national incidence and mortality burden of non-COVID-19 lower respiratory infections and aetiologies, 1990-2021: a systematic analysis from the Global Burden of Disease Study 2021. Lancet Infect Dis. 2024;24(9):974-1002.
2. Safiri S, et al. Global burden of acute lower respiratory infections. The Lancet Infectious Diseases. 2023;23(4):456–468.
3. Simbolon PT, Wulandari RA. Hubungan lingkungan fisik dengan kejadian ISPA pada balita di wilayah perkotaan Indonesia (analisis Riskesdas 2018). Jambura Journal of Health Sciences and Research. 2022;4(2).
4. Birawida AB, Selomo M, Anwar A. Indoor air quality and acute respiratory infections in dense settlements. Journal of Environmental Health Research. 2023;18(1):55–63.
5. Adriansyah A, Rahman A, Putri DA. Hubungan kondisi lingkungan hunian bersama dengan kejadian infeksi saluran pernapasan akut. Jurnal Kesehatan Lingkungan. 2021;13(2):85–93.
6. Holden K, Lee AR, Hawcutt D, Sinha I. The impact of poor housing and indoor air quality on respiratory health in children. Breathe. 2023;19:e230058.
7. Simanjuntak J, Santoso E, Marji. Klasifikasi penyakit infeksi saluran pernapasan akut (ISPA) dengan menerapkan metode Fuzzy K-Nearest Neighbor. Jurnal Pengembangan Teknologi Informasi dan Ilmu Komputer. 2021;5(11):5023–5029.
8. Gold T, McPhaul K, Lin H, Doughty R, Berry IM, Hong F, et al. Impact of ventilation on respiratory virus transmission in college residence hall cohorts: potential for causal inference about mode of transmission. Influenza Other Respiratory Viruses. 2025;19:e70133.
9. Abdollahzadeh N, Farahani AV, Soleimani K, Zomorodian Z. Indoor environmental quality improvement of student dormitories in Tehran, Iran. International Journal of Building Pathology and Adaption. 2022; 14(1): 258-278.
10. Itaqullah YI, Riyanto A, Nugraheni DK, Mauliku N. Analysis of factors related to the incidence of acute respiratory infections in students at Ma'had Ibnul Mubarok Islamic Boarding School Samarinda City 2025. J Riset Kesehat. 2026;15(1): 139-148.
11. Lestari S, Barkah A. Hubungan tingkat pengetahuan ibu tentang ISPA dengan kejadian ISPA pada balita. Jurnal Keperawatan PPNI Jawa Barat. 2023;1(1):43–54.
12. Nanda M, Nasution DA, Azzahra F, Audina S. Kejadian ISPA di Lingkungan Puskesmas Rengas Pulau. Jurnal Kesehatan Tambusai. 2024;5:1128–1136.
13. Rini. Hubungan personal hygiene dan kondisi lingkungan dengan kejadian skabies di Pondok Pesantren Darul Ulum Widodaren Kabupaten Ngawi. Program Studi S1 Kesehatan Masyarakat STIKES Bhakti Husada Madiun. 2019;1(1).
14. Sungkar S. Buku_skabies. 2016:60–65.
15. Kementerian Kesehatan Republik Indonesia. Peraturan Menteri Kesehatan Republik Indonesia Nomor 1077/MENKES/PER/V/2011 tentang Pedoman Penyehatan Udara Dalam Ruang Rumah. Jakarta: Kemenkes RI; 2011.
16. Agustia Pratiwi M, Bintara A, Samsualam. Kejadian infeksi saluran pernapasan akut (ISPA) di Lembaga Pemasyarakatan Narkotika Kelas II A Sungguminasi Gowa. Journal of Muslim Community Health (JMCH). 2022;3(3):13–28.
17. Jedua H, Ripiye SE, Mafe AN, Mafe AL, Edo G, Essaghah AEA, et al. Architectural ventilation deficiency and microbial amplification in internalized sanitary spaces: implications for indoor environmental health and food contamination in tropical buildings. Ecological Frontiers. 2027; 47(1): 1−24
18. Yustati E. Hubungan kepadatan hunian, ventilasi dan pencahayaan dengan kejadian ISPA pada balita. Cendekia Medika. 2020;5(2):107–112.
19. Sulistiarini, Fitriatul, Porusia M, Asyfiradayati R, Halimah S. Hubungan faktor lingkungan fisik dan personal hygiene dengan kejadian skabies di pondok pesantren. Jurnal Kesehatan. 2022;15(2):137–150.
20. Yang, F., Sun, Y.-X., Wang, P., Weschler, L. B., & Sundell, J. Spread of respiratory infections in student dormitories in China. The Science of the total environment. 2021; 777: 145983
21. Marasinghe, S. A., Sun, Y.-X., Norbäck, D., & Mlambo, J. Indoor environment in Sri Lankan university dormitories: Associations with ocular, nasal, throat and dermal symptoms, headache, and fatigue among students. Building and Environment. 2024;257:111194.
22. Sun, C.-J., J., Chen, J.-Y., Huang, C., & Li, J.-G. An orthogonal experiment study of NH3 concentration and its influencing factors in non-newly constructed university dormitories. Air Quality, Atmosphere & Health. 2024;17:2801-2818.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Salsabila Putri Octaly, Kamsul, Intan Kumalasari, Ayu Febri Wulanda, Pitri Noviadi

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

















